<?xml version="1.0"?>
<feed xmlns="http://www.w3.org/2005/Atom" xml:lang="en">
	<id>https://wiki.interactive-asia.com/index.php?action=history&amp;feed=atom&amp;title=Release_Notes</id>
	<title>Release Notes - Revision history</title>
	<link rel="self" type="application/atom+xml" href="https://wiki.interactive-asia.com/index.php?action=history&amp;feed=atom&amp;title=Release_Notes"/>
	<link rel="alternate" type="text/html" href="https://wiki.interactive-asia.com/index.php?title=Release_Notes&amp;action=history"/>
	<updated>2026-04-22T17:15:02Z</updated>
	<subtitle>Revision history for this page on the wiki</subtitle>
	<generator>MediaWiki 1.31.1</generator>
	<entry>
		<id>https://wiki.interactive-asia.com/index.php?title=Release_Notes&amp;diff=212&amp;oldid=prev</id>
		<title>Strohmy: Created page with &quot;'''2019-01-26 1.2.3'''  *Fix error causing Windows Touch input to fail with &quot;The parameter is incorrect&quot; *Fix serial port settings not correctly restoring in the GUI *Fix star...&quot;</title>
		<link rel="alternate" type="text/html" href="https://wiki.interactive-asia.com/index.php?title=Release_Notes&amp;diff=212&amp;oldid=prev"/>
		<updated>2019-03-16T11:30:32Z</updated>

		<summary type="html">&lt;p&gt;Created page with &amp;quot;&amp;#039;&amp;#039;&amp;#039;2019-01-26 1.2.3&amp;#039;&amp;#039;&amp;#039;  *Fix error causing Windows Touch input to fail with &amp;quot;The parameter is incorrect&amp;quot; *Fix serial port settings not correctly restoring in the GUI *Fix star...&amp;quot;&lt;/p&gt;
&lt;p&gt;&lt;b&gt;New page&lt;/b&gt;&lt;/p&gt;&lt;div&gt;'''2019-01-26 1.2.3'''&lt;br /&gt;
&lt;br /&gt;
*Fix error causing Windows Touch input to fail with &amp;quot;The parameter is incorrect&amp;quot;&lt;br /&gt;
*Fix serial port settings not correctly restoring in the GUI&lt;br /&gt;
*Fix start angle calculation for Hokuyo sensors. This was a regression introduced in version 1.2.0 which caused certain models of Hokuyo sensors to be incorrectly rotated.&lt;br /&gt;
*Disabled bilateral filter by default. Filter causes problems in certain situations and there is not enough benefit to keep it enabled. This can be re-enabled in the advanced settings.&lt;br /&gt;
*Replaced bitmap icons with vector icons. This makes the icons look better on high DPI systems or when the display is scaled up.&lt;br /&gt;
*Adjusted UI to make more buttons fit.&lt;br /&gt;
*Added new advanced settings window. This contains settings that usually do not need to be changed but can provide benefits in some situations.&lt;br /&gt;
*Added new translations to Arabic, French, Portugese, Spanish and Thai.&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
'''2018-09-19 1.2.2'''&lt;br /&gt;
&lt;br /&gt;
*Fixed LMS500 series missing scan configurations&lt;br /&gt;
*Added option to ignore unknown version messages from Sick devices (default)&lt;br /&gt;
*Check that the graphics card supports OpenGL 2.0&lt;br /&gt;
*Improved handling of invalid license files crashing the software on startup&lt;br /&gt;
*Fixed crash on loading older files without Windows Mouse mode setting&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
'''2018-06-12 1.2.1'''&lt;br /&gt;
&lt;br /&gt;
*Added optional new dongle licensing method&lt;br /&gt;
*Added optional test mode license, software will require intervention after 1 to 3 hours&lt;br /&gt;
*Added optional license expiry based on system date&lt;br /&gt;
*Fixed crashes on network read timeout and some other error cases on Sick and Leuze devices&lt;br /&gt;
*Add support for LeiShen N301 series devices&lt;br /&gt;
*Allow independent TUIO outputs for multiple devices&lt;br /&gt;
*Fixed bug where trying to stop a device during the reconnect interval would not stop it&lt;br /&gt;
*Added new dongle licensing system&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
'''2018-05-23 1.2.0'''&lt;br /&gt;
&lt;br /&gt;
*Added LIDAR OSC output method (experimental, must be activated in the license)&lt;br /&gt;
*Added support for Hokuyo lasers with &amp;gt; 180 degree range, defaults to 180 but can be changed in the config file&lt;br /&gt;
*Flush Hokuyo input buffers on reconnect to support more reliable connections when the laser is running already&lt;br /&gt;
*Fixed crash on Hokuyo laser timeouts&lt;br /&gt;
*Fixed shadow filter intialization on Hokuyo sensors&lt;br /&gt;
*Added linear regression, defaults to disabled&lt;br /&gt;
*Fixed minimum touch age in the debug settings not loading from file correctly&lt;br /&gt;
*Fixed crash with Leuze ROD4 sensors&lt;br /&gt;
*Fixed crash when stopping a device&lt;br /&gt;
*Updated all library dependencies to their newest versions&lt;br /&gt;
*Removed Windows XP support, if this is needed it can be readded, contact us&lt;br /&gt;
*Changed minimum Mac OS X version to 10.11 (El Capitan)&lt;br /&gt;
*Changed minimum Linux version to Ubuntu 16.04 Xenial Xerus or Debian 8 Jessie&lt;br /&gt;
*Improved OpenGL rendering performance&lt;br /&gt;
*Changed Windows mouse output to just &amp;quot;Mouse&amp;quot;, which is available on all supported platforms&lt;br /&gt;
*Fixed startup warning about being unable to load &amp;quot;C&amp;quot; translation files&lt;br /&gt;
*Changed windows touch default pressure to 0, which means there is no pressure information&lt;br /&gt;
*Fixed minimum touch age not loading from file correctly&lt;br /&gt;
*Fixed using the server application with Windows display scaling enabled&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
'''2016-10-28 1.1.2'''&lt;br /&gt;
&lt;br /&gt;
*Fix default port of sensors&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
'''2016-10-28 1.1.1'''&lt;br /&gt;
&lt;br /&gt;
*Fix code generation problems in release build causing faulty SIMD code being generated. This should fix the new windows mouse mode.&lt;br /&gt;
*2016-10-26 1.1.0&lt;br /&gt;
*Disable invalid value interpolation by default&lt;br /&gt;
*Add configuration for bilateral filter and invalid value interpolation to debug window&lt;br /&gt;
*Add support for USB dongles&lt;br /&gt;
*Add support for Hokuyo sensors connected by USB&lt;br /&gt;
*Add support to automatically detect the specs of Hokuyo sensors&lt;br /&gt;
*Fix values below minimum distance (measurement errors) for Hokuyo sensors&lt;br /&gt;
*Change recording file format to record the sensors minimum and maximum distance, angular resolution, start angle and data point count&lt;br /&gt;
*Added two click windows mouse mode. In two click mode, the first touch point sets the position of the mouse cursor, and the second touch points presses a button. Depending on the side of the first point the second point is on, either the left or the right mouse button is pressed.&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
'''2016-03-12'''&lt;br /&gt;
&lt;br /&gt;
*Fix device screen association selection reset&lt;br /&gt;
*Prevent closing of render window&lt;br /&gt;
*Enable output screen selection&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
'''2016-03-02'''&lt;br /&gt;
&lt;br /&gt;
*Improve default filtering parameters&lt;br /&gt;
*Simplify kalman filter configuration&lt;br /&gt;
*Fixed pausing of log window&lt;br /&gt;
*Fixed log window icon&lt;br /&gt;
*Added more tooltips&lt;br /&gt;
*Enable n-to-1 filter on Sick LMS1xx&lt;br /&gt;
*Enable multi echo filter on Sick LMS5xx&lt;br /&gt;
*Improved touch detection&lt;br /&gt;
*Fixed small cursor prediction problems&lt;br /&gt;
*Add shadow filter for Hokuyo lasers&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
'''2015-12-21'''&lt;br /&gt;
&lt;br /&gt;
*Add support for Sick LMS50, LMS100 and LMS500 devices&lt;br /&gt;
*Fixed loading of device address and port&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
'''2015-12-11 #1'''&lt;br /&gt;
&lt;br /&gt;
*Show license features under Help|Show license&lt;br /&gt;
*Fix crash on exit with running device&lt;br /&gt;
*Add log window&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
'''2015-11-01 #1'''&lt;br /&gt;
&lt;br /&gt;
*Add support for Windows touch injection&lt;br /&gt;
*Mark outputs that are not working with a color and a warning message&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
'''2015-10-29 #1'''&lt;br /&gt;
&lt;br /&gt;
*Add beta support for Leuze RSL400 devices (beta license required)&lt;br /&gt;
*Automatically select newly created devices, screens and outputs for editing&lt;br /&gt;
*Add support for Windows mouse emulation&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
'''2015-10-02 #1'''&lt;br /&gt;
&lt;br /&gt;
*Add file selection dialog when no server configuration file is selected (only on Windows)&lt;br /&gt;
*Add language selection to the user interface&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
'''2015-10-01 #1'''&lt;br /&gt;
*Fix server not processing touches&lt;br /&gt;
*Change touch detection merge algorithm to better handle close points&lt;br /&gt;
*Set default value for merge distance to 80mm&lt;br /&gt;
*Set default value for max. tracking distance to 400mm&lt;br /&gt;
*OpenGL updates do no longer block the user interface, which makes interaction while the sensor is running much more smooth&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
'''2015-09-30 #1'''&lt;br /&gt;
&lt;br /&gt;
*Add first version of Mac OS X build&lt;br /&gt;
*Fix localization problems on Linux&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
'''2015-09-26 #1'''&lt;br /&gt;
&lt;br /&gt;
*Add first version of Linux build&lt;br /&gt;
*Add first version of server component&lt;br /&gt;
*Improve license error reporting&lt;br /&gt;
*Properly handle UTF8 output on all supported platforms&lt;br /&gt;
*Change license file extension from .xml to .otlic&lt;br /&gt;
*Only install translation files in non english locales&lt;br /&gt;
*Improve file dialogs on Linux, always add file extensions&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
'''2015-09-19 #1'''&lt;br /&gt;
&lt;br /&gt;
*Improve deployment and localization&lt;br /&gt;
*Fix update rate calculation counting state changes as outline updates&lt;br /&gt;
*Fix stop state handling&lt;br /&gt;
*Remove unused code&lt;br /&gt;
*Make Linux build work again&lt;br /&gt;
*Add license features&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
'''2015-09-13 #1'''&lt;br /&gt;
&lt;br /&gt;
*Initial release&lt;/div&gt;</summary>
		<author><name>Strohmy</name></author>
		
	</entry>
</feed>